3.2.11. Traffic Control Setup, Continued

Allow Exit: Associated with Deny Other Traffic, allows a service denied error to be
followed with this option and will turn on any traffic devices (lights, gates). This is
recommended for unattended sites to allow the rest of the vehicles to be processed.

This Unit Loading: Used when two terminals are controlling traffic across the scale.
When the unit is in the process of loading a vehicle on the scale it will turn this output
on. This allows the other unit to know that it cannot be process a transaction.

Other Unit Loading: Used when two terminals are controlling traffic across the
scale. This unit will only read this output. The other terminal will turn this output on
when it is loading a vehicle. That tells this unit that it cannot process a transaction.

Screen: Determines what screen is displayed on the screen when the vehicle is
being loaded. In most cases Instructional should be used, and if the Access Unit is
not on the scale then None or Please Wait should be used.

Tracing: Turns on additional diagnostic data when terminal is ready or loading a
vehicle on the scale. This should not be left on unless troubleshooting an issue.

SCREEN PORTION 2 Detect Weight on Scale - These settings determines how a
vehicle is detected to be fully on the scale.

By weight with ##### lb/kg threshold

-

If weight does not equal or exceed

set ####, then vehicle not present.

Stable after ###### readings
(change)

-

Number of consecutive and

identical reads to determine if

weight is stable.

By sensors (such as photo eyes)

-

Inbound and Outbound both have a

input selection and latch time in “s”.