3.4.3. I/O Diagnostics, Continued
Advanced Mode – Behavior: This determines how the output will behave. It has the
following settings.
Advanced Mode Action options:
•
None - If this is selected, the output is not changed at all.
•
Simple Delay - If this is selected, the output will be turned on or off and then
switched back after the number of seconds specified by the delay.
•
Transaction End - If this is selected, the output will be turned on or off and
then switched back after the transaction has ended. If there is a non- zero
value in the delay, the switch back of the output will be delayed for that
amount of time after the transaction has ended.
•
Zeroed Scale - If this is selected, the output will be turned on or off and then
switched back after the scale has gone to zero. If there is a non- zero value in
the delay, the switch back of the output will be delayed for that amount of time
after the scale has gone to zero.
•
Vehicle has Left - If this is selected, the output will be turned on or off and then
switched back after the vehicle has left. If there is a non- zero value in the
delay, the switch back of the output will be delayed for that amount of time
after the vehicle has left.