enFORCE

DSP1500 Main Unit Hardware Manual

PAGE 5 - 5

(Rev. 4.0)

Chapter 5: Control Interfaces

5.3 Discrete I/O Interface

The Discrete I/O Interface is commonly used for direct connect PLC applications. Although, each
individual DSP1500 Servo Controller can also be wired directly to a PLC through its own PLC I/O
port (for individual control).

5.3.1 Sinking Type (NPN)




























Discrete I/O (Sinking Type) Board Specifications

Operating Voltage

24 VDC

Maximum current (outputs) 200 ma

Logic True

Low

(Sinking)

Mating Connectors

PLC-IN

Connector: Honda #MR-34F
Housing: Honda #MR-34L

PLC-OUT

Connector: Honda #MR-34M
Housing: Honda #MR-34L


CN3

CN4

12

1

13

23

22

34

34

23

13

1

12

22

HOME