PAGE 5 - 4
Chapter 5: Control Interfaces
5.2.2 Jog (Manual) Operation
Signal Timing
JOG
OFF
ON
START
OFF
ON
RETURN
OFF
ON
(OPERATION)
Jog
Advance
Jog
Return
BUSY
OFF
ON
READY
OFF
ON
Press Selection (Press No. 4)
PRESS SEL. 0
OFF
ON
PRESS SEL. 1
OFF
ON
PRESS 0 SEL’D
OFF
ON
PRESS 1 SEL’D
OFF
ON
The Jog input must be high (on) to perform manual operations.
While the Jog input is active, a Start input will advance the press as long as the signal is
maintained.
While the Jog input is active, a Return input will return the press as long as the signal is
maintained.
It is recommended when changing press selections that the Select outputs be used to verify that
the desired press number has been changed before issuing a movement signal (Start, Return).
Delay from Press Select input to Press Selected output is approximately 5ms.
The Jog operations are used to move the press under “no load” conditions unless a Bonding
type press is used. Attempting to press a part or move the press under load conditions while
using a Fitting type press may cause an abnormal. If Jog operations are required under “load”
conditions, use a Bonding type press.
Allow a minimum of 20ms to interlock the Press
Select Command and the Start / Return signal.
Approximately 5ms (see notes below)
* No bit selected = Press No. 1