Enforce – FEC DSP1500 Main Unit User Manual
Page 117

enFORCE
DSP1500 Main Unit Hardware Manual
PAGE 5 - 77
(Rev. 4.0)
Chapter 5: Control Interfaces
(Example of Press format selection shown above – this format will be for EACH press
connected in the system)
Press Format
Data
BCD
ACSII
Byte
LSB
Data
MSB
Byte
LSB
Data
MSB
Parameter No.
2 2
02 00
2
30
0
32
2
Cycle Time
12.3 4
00 12 30 00
5
20
31
1
32
2
2E
.
33
3
Judgment Load
12.34 4 00 12 34 00
5
31
1
32
2
2E
.
33
3
34
4
Final Load
Part Check 2
Minimum Load
Part Check 2
Maximum Load
Part Check 3
Minimum Load
Part Check 2
Maximum Load
Judgment Distance
123.456 4 01 23 45 60
7
31
1
32
2
33
3
2E
.
34
4
35
5
36
6
Final Distance
Distance Measurement
Start Distance
Interference Check
Distance
Part Check 1 Distance
Part Check 2 Distance
at Minimum Load
Part Check 2 Distance
at Minimum Load
Part Check 2 Distance
at Minimum Load
Part Check 2 Distance
at Minimum Load
Absolute Distance
Press Number
3 2
03 00
2
30
0
33
3
Judgment
Next
Page
2
(1) (2) (3)
00
← Same Data as BCD
* When outputting BCD the data is formatted as [ 2 byte integer ] [ 2 byte decimal ].
Abnormal Data
Judgment Byte 1
Judgment Byte 2