Figure 5-3. opto 22 digital boards – Micromod Micro-DCI: 53MC5000 PLC AND PRINTER INTERFACES User Manual
Page 51

CONTIGUOUS DIGITAL BOARDS 0 - 15
BOARD
ADDRESS
MODULE NUMBER
NUMBER OF
ACTIVE
CONTIGUOUS
BOARDS
B665/B641
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
(DDI-A AND DDI-B DATAPOINTS ARE SHOWN VERTICALLY BELOW)
0
L L
1 1
5 0
3 2
6 4
L L
1 1
5 0
3 2
7 5
L L
1 1
5 0
3 2
8 6
L L
1 1
5 0
3 2
9 7
L L
1 1
5 0
4 2
0 8
L L
1 1
5 0
4 2
1 9
L L
1 1
5 0
4 3
2 0
L L
1 1
5 0
4 3
3 1
L L
1 1
5 0
4 3
4 2
L L
1 1
5 0
4 3
5 3
L L
1 1
5 0
4 3
6 4
L L
1 1
5 0
4 3
7 5
L L
1 1
5 0
4 3
8 6
L L
1 1
5 0
4 3
9 7
L L
1 1
5 0
5 3
0 8
L L
1 1
5 0
5 3
1 9
1
DDI-A B667 [DDI-B B643] = EVEN BOARD MODULE OUTPUTS (E.G., IF B667 [OR
B643] = 10, THEN L1536 [L1024] TO L1545 [L1033] ARE OUTPUT MODULE
SLOTS AND L1546 [L1034] TO L1551 [L1039] ARE INPUT MODULE SLOTS).
1
L L
1 1
5 0
5 4
2 0
L L
1 1
5 0
5 4
3 1
L L
1 1
5 0
5 4
4 2
L L
1 1
5 0
5 4
5 3
L L
1 1
5 0
5 4
6 4
L L
1 1
5 0
5 4
7 5
L L
1 1
5 0
5 4
8 6
L L
1 1
5 0
5 4
9 7
L L
1 1
5 0
6 4
0 8
L L
1 1
5 0
6 4
1 9
L L
1 1
5 0
6 5
2 0
L L
1 1
5 0
6 5
3 1
L L
1 1
5 0
6 5
4 2
L L
1 1
5 0
6 5
5 3
L L
1 1
5 0
6 5
6 4
L L
1 1
5 0
6 5
7 5
2
DDI-A B668 [DDI-B B644] = ODD BOARD MODULE OUTPUTS (E.G., IF B668 [OR
B644] = 12, THEN L1552 [L1040] TO L1563 [L1051] ARE OUTPUT MODULE
SLOTS AND L1564 [L1052] TO L1567 [L1055] ARE INPUT MODULE SLOTS).
2
•
•
•
15
IN MODULE SLOTS L1568 [L1056] THROUGH L1791 [L1279] FOR BOARDS 2-15:
DDI-A B667 [DDI-B B643] SELECTIONS APPLY TO EVEN BOARD ADDRESSES,
DDI-A B668 [DDI-B] B644 SELECTIONS APPLY TO ODD BOARD ADDRESSES,
WATCHDOG DELAY DDI-A B671 [DDI-B B647] APPLIES TO ALL BOARD OUTPUT
MODULES.
3
•
•
•
16
CONTIGUOUS DIGITAL BOARDS 16 - 31
BOARD
ADDRESS
MODULE NUMBER
NUMBER OF
ACTIVE
CONTIGUOUS
BOARDS
B666/B642
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
(DDI-A AND DDI-B DATAPOINTS ARE SHOWN VERTICALLY BELOW)
16
L L
1 1
7 2
9 8
2 0
L L
1 1
7 2
9 8
3 1
L L
1 1
7 2
9 8
4 2
L L
1 1
7 2
9 8
5 3
L L
1 1
7 2
9 8
6 4
L L
1 1
7 2
9 8
7 5
L L
1 1
7 2
9 8
8 6
L L
1 1
7 2
9 8
9 7
L L
1 1
8 2
0 8
0 8
L L
1 1
8 2
0 8
1 9
L L
1 1
8 2
0 9
2 0
L L
1 1
8 2
0 9
3 1
L L
1 1
8 2
0 9
4 2
L L
1 1
8 2
0 9
5 3
L L
1 1
8 2
0 9
6 4
L L
1 1
8 2
0 9
7 5
1
DDI-A B669 [DDI-B B645] = EVEN BOARD MODULE OUTPUTS (E.G., IF B669 [OR
B645] = 6, THEN L1792 [L1280] TO L1797 [L1285] ARE OUTPUT MODULE SLOTS
AND L1798 [L1286] TO L1807 [L1295] ARE INPUT MODULE SLOTS).
17
L L
1 1
8 2
0 9
8 6
L L
1 1
8 2
0 9
9 7
L L
1 1
8 2
1 9
0 8
L L
1 1
8 2
1 9
1 9
L L
1 1
8 3
1 0
2 0
L L
1 1
8 3
1 0
3 1
L L
1 1
8 3
1 0
4 2
L L
1 1
8 3
1 0
5 3
L L
1 1
8 3
1 0
6 4
L L
1 1
8 3
1 0
7 5
L L
1 1
8 3
1 0
8 6
L L
1 1
8 3
1 0
9 7
L L
1 1
8 3
2 0
0 8
L L
1 1
8 3
2 0
1 9
L L
1 1
8 3
2 1
2 0
L L
1 1
8 3
2 1
3 1
2
DDI-A B670 [DDI-B B646] = ODD BOARD MODULE OUTPUTS (E.G., IF B670 [OR
B646] = 3, THEN L1808 [L1296] TO L1810 [L1298] ARE OUTPUT MODULE SLOTS
AND L1811 [L1299]TO L1823 [L1311] ARE INPUT MODULE SLOTS).
18
•
•
•
31
IN MODULE SLOTS L1824 [L1312] THROUGH L2047 [L1535] FOR BOARDS 18-31:
DDI-A B669 [DDI-B B645] SELECTIONS APPLY TO EVEN BOARD ADDRESSES,
DDI-A B670 [DDI-B B646] SELECTIONS APPLY TO ODD BOARD ADDRESSES,
WATCHDOG DELAY DDI-A B672 [DDI-B B648] APPLIES TO ALL BOARD OUTPUT
MODULES.
3
•
•
•
16
Figure 5-3. OPTO 22 Digital Boards
Section 5. OPTO 22 Mode
OPTO
5-5