Gf100 series – Brooks Instrument GF126 User Manual

Page 56

background image

5-4

GF100 Series

Installation and Operation Manual

X-TMF-GF100-Series-MFC-eng

Part Number: 541B137AAG

March, 2013

Section 5 Product Description Code

GF100 Series Ordering Instructions
Refer to the Product Description Codes on the previous pages. Starting from the left, choose the product code
options as follows:

1. Required performance model.

a.Standard Performance, non-PTI: GF100
b.High Performance, non-PTI: GF120
c.High Performance, w/ PTI: GF125
d.High Performance, w/ PTI, w/ROD: GF135

2. Configurability

a.Disabled: X
b.Enabled: C, Standard (not an option for GF135)

3. Specialty Application

a.High Accuracy, for GF125 only: HA
b.Safe Delivery, for GF120 only: SD
c.No Specialty App: XX

4. Valve Configuration

a.Normally Closed: C
b.Normally Open: O

5. Gas or SH MultiFlo Bin

a.If Gas Specific, enter SEMI gas code: ex. 0013, for N2
b.If SH MuliFlow Bin: SHnn, nn being the required SHBin, 40 - 50

6. Maximum Flow

a.If Gas Specific, enter maximum range in sccm, "C" or slm "L": ex. 500C
b.If SH Bin, enter defined maximum flow: ex. 860, choosing SH44, 281 - 860 sccm

7. Fitting

a.Enter 2-character option code as defined: ex. CX, 1 1/8" C Seal 92mm

8. Downstream Condition

a.Outlet to Vacuum: V
b.Outlet to Atmosphere: A

9. Sensor

a.Orthogonal: O, this is default, non-selectable

10.Connector

a.Enter 2-character option code as defined: ex. DX, DeviceNet

11.CSR

a.Customer Special Requirement, contact Brooks Apps Engineering for review of requirement and
creation of CSR: nnnn
b.If DNET connector, CSR required to define DNET attributes: 0924, generic, ODVA Std. configuration
c.None Required: XXXX

12.Auto Shut-Off.

a.Enabled: A
b.Disabled: X

13.Auto Zero

a.Enabled: A
b.Disabled: X

14.Reference Temperature, Operating Temperature in Degrees C

a.0

o

C Reference Calibration (Standard): 000, default

Here is an example of a configured Product Description Code (PDC) for a GF125, Configurable, no Specialty
Application, Valve Normally Closed, MultiFlo for 281-860 sccm, 1 1/8" C Seal 92mm, outlet to Vacuum, default
sensor, DNET, no CSR, Auto Shut Off enabled, Auto Zero disabled and Default Reference Temperature:
GF125CXXC-SH44860C-CXVODX-0924AX-000