6.
Remote Interface communication protocol
The communication protocol includes standard SCPI commands and a few
proprietary commands which follow the SCPI convention.
6.1
Prefaces
The SCPI interface enables users
to operate the model
XLN3640/XLN6024/XLN8018/XLN10014 supply through a computer or a
terminal equipped with IEEE-488.2 GPIB or USB interface. Additionally, it
allows remote control and monitoring.
SCPI IEEE-488.2 version supports multi units control capability that allows a
user to control up to 32 XLN3640/XLN6024/XLN8018/XLN10014 units.
6.2
Parameters Definition
Type
Valid Arguments
" ON" or 1, " OFF" or 0
The data format
integers. Zero, positive and negative integer numeric
values are valid data.
The data format
flexible Numeric Representation. Zero, positive and
negative floating-point numeric values are some
examples of valid data.
Characters enclosed by single or double quotes
Line Feed, Hex code is 0x0Ah
Carriage Return, Hex code is 0x0Dh
End or identify
Note: All commands are terminated with
space is always included in between the command and the parameter.
For example, to set the GPIB address of 10 to a
XLN3640/XLN6024/XLN8018/XLN10014. The command line is sent:
ADDR 10
Note: The
command descriptions. However, users must add them as termination