beautypg.com

5 scpi conformity information, 1 common scpi commands, Scpi conformity information – B&K Precision XLN60026 - Manual User Manual

Page 168: Common scpi commands

background image

72

4.5

SCPI Conformity Information

The power supply is compatible with all IEEE-488.2 and SCPI commands
(1995). Commands are included in SCPI commands (in Vol. 2, 1995).

4.5.1 Common SCPI commands

Command

Explanation

*CLS

Clear status (include error code)

*IDN?

Response:, , ,

*RCL

Recalls settings from memory. Memory numbers from 0
to 9 are valid.

*RST

Resets the power supply to its power on state.

*SAV

1. Saves defined parameters

2. Saves current settings to memory. Memory numbers

from 0 to 9 are valid.

Examples:

Q 23:How to store the voltage/current settings to memory devices?

*SAV 5

==>save current settings to memory location 5

Q 24:How to recall the voltage/current settings from memory
devices?

*RCL 3

==>recall setting from memory location 3

Q 25:How to set up software reset?
*RST
Q 26:How to identify the instrument’s model number?
*IDN?
Q 27:How to clear error message?