beautypg.com

B&K Precision XLN60026 - Manual User Manual

Page 124

background image

28

Users can enable/disable external control in this menu option.
An external voltage source (VOLT) or resistor (RES) can be
used to control the output voltage and current. The external
voltage/resistance can be either 0 - 10V/0 - 10K (10V/10K) or
0 - 5V/0 - 5K (5V/5K). Users can also monitor the output
status by reading the monitoring pins (0 - 10V or 0 - 5V) of the
external analog control interface.

7. TIMER CONTROL

Press

in the third page of menu to enter TIMER CONTROL

screen.

TIMER:

Turn on/off TIMER function.

TIME:

Set up OUTPUT ON time (Max:999Hr 59Min
59Sec)

8. CALIBRATION

Press

in the third page of the menu to enter CALIBRATION

menu. Users must enter the password to access calibration mode. For
calibration details, see “

Calibration

” chapter.

9. Series Connection Control Setting (CHAIN)

Press

in Menu setting page to enter CHAIN SETTING

=

=

FF

r

n

i

ec

:

L