EXTERN

ENABLE

(menu config.)

EXTERN

SHUT-OFF

(menu config.)

Shut-Off

(pin 15)

Output Display

NOT ACTIVE

(by Default)

OFF / LOW

NOT

ACTIVE

On

No

Display

ON / LOW

NOT

ACTIVE

On

No

Display

ACTIVE

OFF / LOW

High-to-Low

Off

SO

ON / LOW

Low-to-High

Off

SO


CV/CC
Pin 13 can be used to monitor the power supply output mode. The pin will
output a High level (5V) under CV mode, and Low level (0V) under CC
mode.

CV/CC

level

Output Mode

Display

High

Constant Voltage

CV

Low

Constant Current

CC

Local/Analog
Pin 8 can be used to select the control mode (Local or Analog) of the power
supply’s output. When the input command for this pin is at High level (or
open), the control mode will be Local. When input command for this pin is
at Low level (or connected to common GND), the control mode will be
Analog. In analog mode, setting and measurement resolution for voltage
and current will be less than local mode. See the below figures as an