4.7.2 Output Control Commands

This set of commands controls the outputs of the selected instrument

(based on their address). Use

CADR command (described in previous

section) first to select the address of the unit you want to control before

using any of these commands to control that unit’s output.

Command

Description

==================================================
CPV

Sets the output voltage value in Volts

CPV?

Reads the output voltage setting

CMV?

Reads the actual output voltage

CPC

Sets the output current value in Amperes

CPC?

Reads the output current setting

CMC

Reads the actual output current

CDVC?

Display voltage and current data

COUT

Turns the output to ON or OFF

COUT?

Returns the output On/Off status

COV

Sets the OVP level

COV?

Returns the OVP setting level

COVP

Sets the OVP on/off

COVP?

Returns the OVP on/off

COC

Sets the OCP level

COC?

Returns the OCP setting level

COCP

Sets the OCP on/off

COCP?

Returns the OCP on/off

COP

Sets the OPP level

COP?

Returns the OPP setting level

COPP

Sets the OPP on/off

COPP?

Returns the OPP on/off

CMODE?

Returns the power supply operation mode

==================================================