Remote Communication

4.1

Interface Connection


USB (Virtual COM)

All models have a standard USB interface (virtual COM) that can be

used for remote communication. The serial settings are listed below:


BAUDRATE: 57600

PARITY: NONE

DATA BITS: 8

STOP BIT: 1
FLOW CONTROL: NONE


GPIB
GPIB option is available when the supply is installed with the optional

LAN/GPIB interface card. Each model can be configured with a GPIB

address from 1 – 30. To communicate via GPIB, connect a GPIB cable

to the GPIB interface of the LAN/GPIB interface card.


Ethernet (LAN)
Ethernet (LAN) option is available when the supply is installed with the

optional LAN/GPIB interface card. There are three ways to control the

power supply via LAN interface: Web server, Telnet connection, and

Socket connection.

There is an embedded web server GUI that can access the power supply

via LAN interface using a Java enabled web browser. The GUI

Web Server