UUT by accidentally entering the wrong settings.

6) Series & parallel connection mode

The series-parallel connection mode of two or more units (maximum to 4
units) significantly increases the combined output power to a maximum of
5760 W. In parallel connection mode of four XLN3640 the maximum
output is 36 V/160 A; and in series connection mode of four XLN10014,
the maximum output is 400 V/14.4 A.

7) Multi-unit connection mode

The RS 485 interface can be used to connect multiple power supplies in
series, up to maximum of 30 units. They can be controlled via USB
interface with a computer.