beautypg.com

Rainbow Electronics DS2180A User Manual

Page 24

background image

DS2180A

041995 24/36

193E FRAMING FORMAT Table 7

FRAME

F-BIT USE

BIT USE IN EACH CHANNEL

SIGNALING-BIT USE

FRAME

NUMBER

FPS

1

FDL

2

CRC

3

DATA

SIGNALING

2

STATE

4

STATE

16

STATE

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

0

0

1

0

1

1

M

M

M

M

M

M

M

M

M

M

M

M

C1

C2

C3

C4

C5

C6

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–7

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–7

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–7

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–8

BITS 1–7

BIT 8

BIT 8

BIT 8

BIT 8

A

A

A

A

A

B

A

B

A

B

C

D

NOTES:

1. FPS – Framing Pattern Sequence.

2. FDL – 4 KHz Facility Data Link; M = message bits.

3. CRC – Cyclic Redundancy Check bits. The CRC code will be internally generated by the device when

TCR.5=0. When TCR.5=1, externally supplied CRC data will be sampled at TSER during the F-bit time of
frames 2, 6, 10, 14, 18, 22.

4. The user may program any individual channels clear, in which case bit 8 will be used for data, not signaling.

5. Depending on application, the user can support 2-state, 4-state or 16-state signaling by the appropriate de-

codes of TMO, TSIGFR, TSIGSEL (Transmit Side) and RMSYNC, RSIGFR and RSIGSEL (Receive Side).