Troubleshooting

65

PNEG-720-G2 12" & 16" Series II Sweep

1 Sweep will not run.

a.) Power cords may be unplugged.

a.) Plug in the power cords.

b.) Foot switch may not be actuated.

b.) Make sure the foot switch is

depressed and the switch is
operating properly.

c.) Overloads may be tripped.

c.) Reset the overloads.

d.) Adjustable overloads not set

correctly

d.) Set overload to value listed on

motor name plate for Full Load
Amps.

2 Low capacity.

a.) The auger may not be fully loaded.

a.) Make sure the grain is flowing into

the auger, making it fully loaded.

b.) The auger is moving too slowly.

b.) Check the auger speed. Low

capacity will result from speeds
slower than recommended.

3 Sweep will not move

around the bin.

a.) The control panel may not be in

"Automatic Mode".

a.) Turn the switch to "Automatic

Mode".

b.) Tha amp meter is not properly

adjusted.

b.) Set the amp meter so the running

amps of the auger motor will turn
on the drive motor.

c.) The drive chain may be broken.

c.) Repair the drive chain.

4 The sweep is vibrating. a.) The auger may have foreign materials

in it.

a.) Remove the foreign material.

b.) The hanger bearings may be worn.

b.) Replace the hanger bearing.

c.) The flight connections may be loose. c.) Tighten all of the flight connecting

bolts.

d.) The flighting may be worn.

d.) Replace all the flighting sections

that are worn.

Solution

Possible Cause

Problem