See the chart for the correct size of conduit to the corresponding sweep size.

15. ELECTRICAL ASSEMBLY

Caution! All electrical wiring and service work must be performed by a qualified
electrician and must meet all State and Local electrical codes.

Sweep Section Conduit Sizes

Bin

10' Conduit

Other

Diameter

Pieces

Pieces

36'

N/A

1 @ 9'

37'

1

N/A

39'-40'

1

1 @ 1'

42'

1

1 @ 2'

43'-45'

1

1 @ 3'

48'-49'

1

1 @ 5'

51'

1

1 @ 6'

54'-55'

1

1 @ 8'

57'

1

1 @ 9'

59'

2

N/A

60'

2

1 @ 1'

62'-63'

2

1 @ 2'

66'

2

1 @ 4'

68'-69'

2

1 @ 5'

72'

2

1 @ 7'

75'

2

1 @ 8'

78'

3

N/A

80'-81'

3

1 @ 1'

84'

3

1 @ 3'

87'

3

1 @ 4'

88'

3

1 @ 5'

90'-91'

3

1 @ 6'

92'

3

1 @ 7'

95'

3

1 @ 8'

98'

4

N/A

105'

3

1 @ 9'

113'-120'

4

N/A

A. Place the 3/4" rigid conduit in order starting with the head section

and working towards the tail or extension section.

B. Connect the rigid conduit together using one (1) 3/4" conduit

coupling between each piece of conduit.

3/4" conduit
coupling

3/4" rigid
conduit

3/4" rigid
conduit

FIG. 15-B