58

12" & 16" Series II Sweep PNEG-720-G2

Maintenance

E. Lubrication – Reducers (Gear Boxes)

Reducers supplied for use on Series 2 Sweeps are shipped without lubricant (dry). The proper
lubricant must be added at the time of installation. Over lubrication may cause premature failure of
the reducer. The amount of lubricant must be carefully controlled.

F. Procedure for Initial Filling of Reducers

1.) Disconnect and lock motor out of service. Do not run gearbox without lubricant.
2.) Follow all safe bin entry procedures and wear all required personal protective equipment.
3.) Remove contaminants from inlet area.
4.) Remove filler and oil level fill plugs.
5.) Check filler holes for blockage and clean as necessary.
6.) Clean the magnetic drain plug if one was supplied.
7.) Add proper type of lubricant to fill level or until oil runs out of oil level fill hole. See the lubrication

chart for amounts and types of lubricant.

8.) Wipe off excess lubricant and replace filler and oil level fill plugs.

NOTE: It is very important to keep the lubricant clean. Also, mixing dissimilar lubricants is not
recommended.

G. Procedure for Changing of Lubricant

1.) Stop motor. Disconnect and lock out of service.
2.) Follow all safe bin entry procedures and wear all required personal protective equipment.
3.) Remove contaminants from inlet and drain area.
4.) Remove filler, oil level fill, and drain plugs. Drain old lubricant from reducer.
5.) Flush reducer with a nonflammable solvent such as Lubriplate Pure Flush or Whitmore’s

Flushing Oil.

6.) Clean the magnetic drain plug if installed.
7.) Carefully replace drain plug.
8.) Add proper type of lubricant to fill level or until oil runs out of oil level fill hole. See the lubrication

chart for amounts and types of lubricant.

9.) Wipe off excess lubricant and replace filler and oil level fill plugs.

NOTE: It is very important to keep the lubricant clean. Also, mixing dissimilar lubricants is not
recommended.

H. Frequency of Lubrication

Lubricant should be changed after storage of one year or more or at the beginning of each season.

I. Type of Lubrication

The type and quantity of lubrication required, for each type and size of reducer, is listed in the
following chart.

2. LUBRICATION (CONT.)