Assembly – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1579 User Manual
Page 60
![background image](/manuals/277850/60/background.png)
48
12" & 16" Series II Sweep PNEG-720-G2
Assembly
B. Center Pivot For Standard Sweep
The center pivot for a standard sweep must be supplied by the customer.
The following are requirements for installation.
1. The cross braces must be 1/2" steel plate.
2. The pivot pin must be 1-1/2" diameter steel bar and extend approximately 4" above floor
elevation.
The pivot pin MUST be in the center of the bin. If it is not, the sweep
could hit the bin wall.
17. CENTER PIVOT INSTALLATION (cont.)
18. CONTROL PANEL SETUP
A. Find the desired "High" amp and "Low" amp set points.
1. High Amp Set Point: The amp load the auger draws when the auger flighting is 90% loaded.
This will turn off the tractor drive motor. Initially, set the value to 90% of the Full Load Amps
(FLA) listed on the motor nameplate.
2. Low Amp Set Point: The amp load the auger motor draws the auger flighting 10% loaded.
This will turn on the drive motor. Initially, set this value to 10% over the amp draw of the sweep
running empty.
The bin must have grain in it to be able to properly program the control panel.
NEVER program the "High Amp Set Point" greater than the full load
running amps of the auger motor.
B. Programming the Amp Meter
1. Setting Input
a. Press "PRGM" to "inPut".
b. Press "ENTER".
c. Press "PRGM" to "i4-20".
d. Press "ENTER" to RUN MODE.
2. Setting Setup
a. Press "PRGM" to "SEtuP".
b. Press "ENTER" to "rdEC"
Use arrow buttons to change the decimal placement. Show .0 Amps.
c. Press "ENTER" to "SETLO"
d. Press "ENTER"
Value = 0.0
e. Press "ENTER" to "SEtHi".
The Series 2 Sweep is supplied with adjustable overlaods that are not set at the factory. These
should be set slightly higher than the full load amp (FLA) value listed on the motor nameplates.