General Product Information
19
PNEG-720-G2 12" & 16" Series II Sweep
B. A magnetic starter should be used to protect the motor when starting and stopping. It should stop
the motor in case of power interruption, conductor fault, low voltage, circuit interruption or motor
over load. The motor must be restarted manually. Some motors have built-in thermal overload
protection. If this is the type of motor being used, use only those with a manual reset.
C. The motor starting controls must be located outside the bin. They must NEVER be installed on the
Series II auger inside the bin.
D. Disconnect and lockout the power before resetting motor overloads.
E. Disconnect and lockout the power before entering the bin.
F. Disconnect and lockout the power before servicing the equipment.
G. Position the reset and motor starting controls so that the operators have full view of the equipment
3. CAPACITIES AND SPECIFICATIONS (CONT.)
H. Make sure electric motors are grounded.
There should ALWAYS be two (2) people in the work area.
A main power disconnect switch capable of being locked only in the OFF position should
be used. It should be locked whenever work is being done on the Series II Sweep.