50
12" & 16" Series II Sweep PNEG-720-G2
Start-Up
1. PERFORM PRE-START CHECKS
A. Make sure ALL shields are in place.
ALWAYS keep ALL guards and shields in place, until all the power is
disconnected and locked out.
B.
Inspect the drive unit for any problems or potential problems.
C. Be aware of any emergency shutdown procedures. Two (2) people must always be in a position
where the operation of the equipment can be monitored.
D. Before starting the auger for the first time, make sure that all parts are assembled correctly accord-
ing to the instructions in this manual.
Danger! Failure to perform any or all of these pre-start checks may cause
damage to the equipment and/or cause SERIOUS INJURY or DEATH to those
in the work area.
Failure to perform any or all of these pre-start checks may also be a misuse of
the equipment. Any misuse of the equipment may void the warranty.
Warning! To ensure that the drive is not unexpectedly started, turn off and
lock out or tag out the power source before proceeding. Failure to observe
these precautions could result in bodily injury.
Make certain ONLY trained operators are in the work area before operating or
moving the machine. Two (2) people must always be in a position where the
operation of the equipment can be monitored.
Be sure to remove the grain from the drive chain and sprockets. If this is not