beautypg.com

M&C TechGroup SP2400-H Operator's manual User Manual

Page 29

background image

2-1.1-ME

Gas sampling and gas conditioning technology

29

16.3

OPTION BALL VALVE DRIVES

For external control of the probe internal ball valves there is the possibility to use a pneumatic drive
with return spring type MS1, MS3 (for 320°C) or an electric drive EA.

16.3.1

OPTION PNEUMATIC DRIVE MS1 OR MS3 WHEN USING A 2/2-WAY BALL
VALVE /VA

Ball valve open = measuring operation

Ball valve closed = e.g. changing filter element at process excess pressure or toxic sample gas or test
gas feeding with option check valve /R without loss of test gas into the process.

Figure 13

Pneumatic drive for 2/2-way ball valve

When placing the order it shall be specified whether the ball valve should be

NC

, without control air closed, or

NO

, without control air open and hence switched to measuring.


Standard = NC