12 receipt of goods and storage, The following prefilters can be selected – M&C TechGroup SP2400-H Operator's manual User Manual
Page 14
14
Gas sampling and gas conditioning technology
2-1.1-ME
The following prefilters can be selected :
Prefilter
Type
Part no.
Temp.
max.
°C
Material
filter / connec-
tion
Filter
porosity
µm
Dust
content
g/m
3
Inside
volume
displacer
Length
mm
Filter
ø mm
Con-
nection
SP2000/20SS 150
20S9160
600
SS316/316Ti
20
2-10
150 31 ø
25
SP2000/V20 20S9085
600
SS316/316Ti
2 2-10
220 46 G
3/4"a
SP2000/V20-0 20S9105
600
SS316/316Ti
2 2-10
X
220 46
G
3/4"a
SP2000/V20/HC 20S9095
900 Hastelloy-C 2
2-10
220 46 G
3/4"a
SP2000/V20-0/HC 20S9115 900 Hastelloy-C
2
2-10 X
220
46 G
3/4"a
SP2000/V20-T
20S9315
200
PTFE / SS316Ti
3
> 10
400 65 G
3/4"a
SP2000/V20-2 20S9125
600
SS316/316Ti
2 >
10
520 60 G
3/4"a
SP2000/V20-1
20S9145
600
SS316/316Ti
2
> 10
X
520
60
G 3/4"a
SP2000/V20-2/HC 20S9135 900 Hastelloy-C
2
>
10
520 60 G
3/4"a
SP2000/V20-1/HC
20S9155
900
Hastelloy-C
2
> 10
X
520
60
G 3/4"a
SP2000/V20-4
1)
20S9290
600
SS316/316Ti 2
2-10
1)
300 31 G
3/4"a
SP2000/V20-3
1)
20S9300
600
SS316/316Ti 2
2-10 X
1)
300 31 G
3/4"a
SP2000/V20-5 20S9127
500
SS316/316Ti
3 2-10
220 50 G
3/4"a
SP2000/V20-6 20S9128
500
SS316/316Ti
3 >
10
520 60 G
3/4"a
SP2000/V12-1 20S9500
1000
Keramik
5)
/
SS316Ti
1 >
10
500 40
DN65
PN6
SP2000/V12-3 20S9510
1000
Keramik
5)
/
SS316Ti
1 >
10
optional
1000
60
DN65
PN6
SP2000/V12-2 20S9505
1000
Keramik
5)
/
SS316Ti
2 >
10
optional
1000
60
DN65
PN6
SP2000/V12-1/SS
2)
20S9525 600
Keramik
5)
/
SS316Ti
1 >
10
500 40
DN65
PN6
SP2000/V12-3/SS
3)
20S9535 600
Keramik
5)
/
SS316Ti
1 >
10
optional
1000
60
DN100
PN6
SP2000/V12-2/SS
3)
20S9530 600
Keramik
5)
/
SS316Ti
2 >
10
optional
1000
60
DN100
PN6
SP2000/V12-1/IC
2)
20S9540 1000
Keramik
5)
/
Incoloy-SS316Ti
1 >
10
500 40
DN65
PN6
SP2000/V12-3/IC
3)
20S9550 1000
Keramik
5)
/
Incoloy-SS316Ti
1 >
10
optional
1000
60
DN100
PN6
SP2000/V12-2/IC
3)
20S9545 1000
Keramik
5)
/
Incoloy-SS316Ti
2 >
10
optional
1000
60
DN100
PN6
1)
Prefilter V20-3, V20-4 optional up to 1000 mm length available.
2)
With protection tube V12-1.
3)
With protection tube V12-2/3.
4)
Prefilter with special construction for efficient back purge.
5)
Please pay attention to the characteristic feature of ceramic in case of high and changing temperatures!
For more information about prefilters see data sheet 2-1.1.0.8
12
RECEIPT OF GOODS AND STORAGE
The gas sample probe and any special accessories should be removed carefully from the packag-
ing and checked immediately for completeness against the delivery note.
Check the goods for any damage incurred during transport and if necessary inform your transport
insurer of any damage.
The gas sample probe is normally delivered in two packaging units:
1. The gas sample probe with the screws, nuts and flange seal required for mounting.
2. Sample tube or prefilter, if applicable with extension tube.