beautypg.com

2 recommended operating conditions – Texas Instruments TSB12LV26 User Manual

Page 86

background image

7–2

7.2

Recommended Operating Conditions

OPERATION

MIN

NOM

MAX

UNIT

VCC

Core voltage

Commercial

3.3 V

3

3.3

3.6

V

VCCP

PCI I/O clamping voltage

Commercial

3.3 V

3

3.3

3.6

V

VCCP

PCI I/O clamping voltage

Commercial

5 V

4.5

5

5.5

V

PCI

3.3 V

0.475 VCCP

VCCP

VIH†

High level input voltage

PCI

5 V

2

VCCP

V

VIH†

High-level input voltage

PHY interface

2

VCCP

V

Miscellaneous‡

2

VCCP

PCI

3.3 V

0

0.325 VCCP

VIL†

Low level input voltage

PCI

5 V

0

0.8

V

VIL†

Low-level input voltage

PHY interface

0

0.8

V

Miscellaneous‡

0

0.8

PCI

3.3 V

0

VCCP

VI

Input voltage

PHY interface

0

VCCP

V

Miscellaneous‡

0

VCCP

§

PCI

3.3 V

0

VCCP

VO§

Output voltage

PHY interface

0

VCCP

V

Miscellaneous‡

0

VCCP

tt

Input transition time (tr and tf)

PCI

0

6

ns

TA

Operating ambient temperature

0

25

70

°

C

TJ¶

Virtual junction temperature

0

25

115

°

C

† Applies for external inputs and bidirectional buffers without hysteresis.
‡ Miscellaneous pins are: GPIO2, GPIO3, SDA, SCL, CYCLEOUT.
§ Applies for external output buffers.