2 recommended operating conditions – Texas Instruments TSB12LV26 User Manual
Page 86

7–2
7.2
Recommended Operating Conditions
OPERATION
MIN
NOM
MAX
UNIT
VCC
Core voltage
Commercial
3.3 V
3
3.3
3.6
V
VCCP
PCI I/O clamping voltage
Commercial
3.3 V
3
3.3
3.6
V
VCCP
PCI I/O clamping voltage
Commercial
5 V
4.5
5
5.5
V
†
PCI
3.3 V
0.475 VCCP
VCCP
VIH†
High level input voltage
PCI
5 V
2
VCCP
V
VIH†
High-level input voltage
PHY interface
2
VCCP
V
Miscellaneous‡
2
VCCP
†
PCI
3.3 V
0
0.325 VCCP
VIL†
Low level input voltage
PCI
5 V
0
0.8
V
VIL†
Low-level input voltage
PHY interface
0
0.8
V
Miscellaneous‡
0
0.8
PCI
3.3 V
0
VCCP
VI
Input voltage
PHY interface
0
VCCP
V
Miscellaneous‡
0
VCCP
§
PCI
3.3 V
0
VCCP
VO§
Output voltage
PHY interface
0
VCCP
V
Miscellaneous‡
0
VCCP
tt
Input transition time (tr and tf)
PCI
0
6
ns
TA
Operating ambient temperature
0
25
70
°
C
TJ¶
Virtual junction temperature
0
25
115
°
C
† Applies for external inputs and bidirectional buffers without hysteresis.
‡ Miscellaneous pins are: GPIO2, GPIO3, SDA, SCL, CYCLEOUT.
§ Applies for external output buffers.
¶ The junction temperatures reflect simulation conditions. Customer is responsible for verifying junction temperature.