Figure 2–8. interrupt initialization sequence – Texas Instruments MSP50C614 User Manual

Page 55

background image

Interrupt Logic

2-25

MSP50C614 Architecture

Figure 2–8 provides an overview of the interrupt control sequence. INT0 is the
highest priority interrupt, and INT7 is the lowest priority interrupt.

Figure 2–8. Interrupt Initialization Sequence

INTD

instruction

CLEAR

INTE

instruction

SET

Global Interrupt Enable

CLEAR

Internal Timer Underflow

External Input Falling-Edge

External Input Rising-Edge

Software Write Instruction†

Interrupt-Trigger Event

SET BIT

INT Flag bits (IFR)

Associated With the Interrupt-Trigger Event

Interrupt Flag Register (0x39)

INT7 INT6

INT5

INT4

INT3 INT2

INT1

INT0

CLEAR BIT

INT Mask bits (IMR)

Specific Enable for Interrupt Service

Interrupt / General Control Register (0x38)†

INT7 INT6

INT5

INT4

INT3 INT2

INT1

INT0

Interrupt Service Branch

Highest Priority INT is Selected From

Among Those Flagged and Enabled.

Program Branches to Location

Stored in Interrupt Vector.

Interrupt

Service

Routine

(1 of 8)

Interrupt Vector Storage

INTE
IRET

0x7FF0

0x7FF2

0x7FF4

0x7FF6

0x7FF1

0x7FF3

0x7FF5

0x7FF7

† The port-addressed write instruction (OUT) can be used to SET or CLEAR bits in the IFR and IMR.