Nortel Networks M3110 User Manual
Page 222

Page 222 of 504
M3900 installation and configuration
553-3001-367 Standard 3.00 August 2005
FINT
sl
Enter starting hour and length for a time interval.
Prompted n times if n>0.
s = starting hour (0-23)
l = length of interval in hours (1-24)
FTNR
(NO) YES
TN range restriction option for Flash Download
NO = no TN restriction (default)
YES = specify TN range
FSTN
Starting Terminal Number for Flash Download. Prompt appears
only if FTNR = YES.
l s c u
Format for Large System and CS 1000E system, where l = loop,
s = shelf, c = card, u = unit
c u
Format for Small System, CS 1000S system, Media Gateway
1000B, and Media Gateway 1000T, where c = card and u = unit
FETN
Ending Terminal Number for Flash Download. Prompt appears
only if FTNR = YES
l s c u
Format for Large System and CS 1000E system, where l = loop,
s = shelf, c = card, u = unit
c u
Format for Small System, CS 1000S system, Media Gateway
1000B, and Media Gateway 1000T, where c = card and u = unit
FDNR
(NO) YES
DN range restriction option for Flash Download
NO = no DN restriction (default)
YES = specify DN range
LD 97 – Configure parameters for System-wide Flash Download (Part 2 of 3)
Prompt
Response
Description