Digital bridge technical, Specifications – Paradyne COMSPHERE 3611 User Manual
Page 77
COMSPHERE 3600 Series Data Service Units
E-4
September 1996
3610-A2-GB48-50
Table E-3
Digital Bridge Technical Specifications
Specifications
3
Criteria
APPLICATION
Digital Bridge
Provides 5-port digital bridging for various applications. Used primarily
for multipoint dial backup, which can be configured as a central-site
bridge or an extended bridge.
PORT SYNCHRONOUS RATES
Primary (DSU) and Backup (DBM)
2.4, 4.4, 4.8, 9.2, 9.6, 12.0, 14.4, 18.8, 19.2, 38.4, 56 and 64 kbps
DIAGNOSTIC SUPPORT
Supports nondisruptive diagnostics (NonD), mixed, and disruptive (Disr)
diagnostic types. The Disruptive Type configuration option must be set
to either 3600e or Br56.
PORT DTE INTERFACE
3610 DSU (2-port TDM/Flex or MCMP/Flex)
3610 DSU (6-port TDM/Flex or MCMP/Flex)
3611 DSU (modular)
3610 DSU (TDM/DSD or MCMP/DSD)
3611 DSU (non-modular)
Provides an additional 25-pin D-subminiature connector, for a total of
two EIA-232 or V.35 interfaces that can be set independently of each
other when you have DSU firmware Release 6.33 or greater.
Provides five additional 25-pin D-subminiature connectors, for a total of
six EIA-232 or V.35 interfaces that can be set independently of each
other when you have DSU firmware Release 6.33 or greater.
Provides a 6-port connector module that provides a total of six 25-pin
D-subminiature EIA-232 connections (including the DSU). In addition, a
26-pin high-density D-type connector provides a V.35 interface through
an adapter cable.
Provides five additional 25-pin D-subminiature connectors that can be
optioned for EIA-232 or V.35, for a total of six EIA-232 or six V.35
interfaces.
Provides one 60-pin high-density D-type connector that provides five
additional EIA-232 interfaces through an adapter cable.
NMS SUPPORT
Digital bridging capability is fully supported by the COMSPHERE 6700
or 6800 Series NMS, Release 4.0 or greater for the 6700 Series NMS
and Release 4.1.5 or greater for the 6800 Series NMS software in ADp
and DATAPHONE II modes.
3
TDM and MCMP circuit cards can both be configured to provide digital bridge capability.