beautypg.com

Digital test, End-to-end test, Bit error rate test – Paradyne COMSPHERE 3611 User Manual

Page 24: Dial tone test

background image

Front Panel Operation

3-9

3610-A2-GB48-50

September 1996

Digital Test

The Digital Test (DT) verifies operation of a pair of

DSUs and the data circuit between them. When a Digital
Test is performed on a specific port, data transmission is
not affected on the other ports.

For a DSU operating in single-port mode and having

either nondisruptive diagnostics or rate adaption in effect,
an additional selection for Aggr or Prt1 appears.

Selecting Aggr tests the looped data path; in-band

communication transport data is not allowed.

End-to-End Test

The End-to-End (EE) test analyzes a control and a

tributary DSU or DBM and the network circuit between
them in both directions independently. Refer to Document
No. 3610-A2-GB46 for additional information.

Bit Error Rate Test

The Bit Error Rate Test (BERT) is session-disruptive

and transmits a test pattern to analyze the network circuit.
Refer to Document No. 3610-A2-GB46 for additional
information.

Dial Tone Test

The Dial Tone test (DTone) allows a DBM to test for

dial tone. This selection does not appear in the DSU’s Test
branch.