Configuration Option Tables

4-15

3610-A2-GB48-50

September 1996

Table 4-4

(5 of 5)

TDM/MCMP Port Configuration Options

*

Upstrm Port:Prt1
Next Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 Prev

Upstream Port. If an extended control DSU has its main (primary) channel connected to a tributary DSU and the
tributary’s Extend Channel configuration option is set to Yes, set this configuration option to the upstream port number.
Select Prt1 if the tributary DSU is operating in single port mode. Ports 3 through 6 do not appear when a 2-port
TDM/Flex or MCMP/Flex is installed.

Prt1 to Prt6 – Selects the upstream port number.

DTE Port: EIA232
Next EIA232 V.35 Prev

DTE Port. Selects the alternate Port 1 or the Port 2 through port 6 interface for data transmission. For TDM/Flex or
MCMP/Flex models, each port is set separately. See the

Reconfiguring Ports section in Chapter 2.

EIA232 – Selects EIA-232 interface connector operation for the port.

V.35 – Selects V.35 interface connector operation for the port.

DCE Type: Analg
Next Analg Digtl Prev

DCE Type. Appears when FEP Port Sharing is enabled (Table 4-1 or 4-2). Applies to even numbered ports only. When
backup initiated, this configuration option specifies what timing source will automatically be in effect.

Analg – Select for analog connection; includes V.32 DBM.

Digtl – Select for digital connection; includes Switched 56 and ISDN DBMs.

* The menu paths for Port 1 through Port 6 are identical; each port is set separately. Ports 3 through 6 do not appear

when a 2-port TDM/Flex or 2-port MCMP/Flex is installed.