beautypg.com

Table d–2, Table d–3 – Paradyne Jetstream CPX-1000 User Manual

Page 151

background image

February 2003

D-3

1000-A2-GN22-00

D. Specifications

Table D–2. CPX-1000 Environmental Specifications

Parameter

Specification

Reference

Operating temperature

5

°C to 40°C (40°F to 104°F)

GR-63-CORE, R4-6, R4-7

Operating humidity

5% to 85% RH, non-condensing

GR-63-CORE, R4-6, R4-7

Storage and transit temperature

–40

°C to +70°C (–40°F to 158°F) GR-63-CORE, R4-3, R4-4

Storage and transit humidity

95% RH at 40

°C (104°F)

GR-63-CORE, R4-5

Altitude

without temperature derating

−60m to 1800m above sea level

(−200 ft to 5905 ft)

GR-63-CORE, R4-8

with temperature derating

1800 to 4000m above sea level
(5095 ft to 13,123 ft)

GR-63-CORE, R4-9, O4-
10

Airborne contaminant

25 ppi pore size, 63% dust
arrest. UL-900 Class V-2, UL 94
H-1 flammability rated

GR-63-CORE, 4.5, R4-59,
O4-60

Table D–3. CPX-1000 Electrical Specifications

Parameter

Specification

Reference/Comment

Electrical safety criteria

GR-1089-CORE,
Section 7.0

Bonding and grounding

Common, integrated ground plane,
multi-point ground

GR-1089-CORE,
Section 9.0

Input voltage range

–40 VDC to –72 VDC A and B input

Corrosion

GR-1089-CORE,
Section 8.0