Hot Swapping
Hot swapping lets you remove and replace cards without shutting
down and reconfiguring the CPX. To hot swap:
an MP card—go to Hot Swapping an MP Card, below
CP and HSC cards—go to page
Line cards—go to page
Hot Swapping
an MP Card
To hot swap an MP card, refer to JetVision User’s Guide and:
Step 1
Back up the current CPX database.
Step 2
Click the MP card in the Tree or Shelf views.
Step 3
Select Remove Resources from the Configuration menu. A
prompt displays to confirm you want to remove the resources.
Step 4
Click Yes. The card is removed from the Tree and Shelf views.
Step 5
Remove and replace with the new cards per
Step 6
Select Refresh CPX from the File menu. The new MP card
appears in the Tree and Shelf views.
Step 7
Restore the CPX configuration.
Important
Do not force the card into place—this may cause damage to
the connector pins.
Notes
Make sure to put on an anti-static wrist wrap when hot
swapping cards. Refer to JetVision User’s Guide.
When removing a card—always remove the processing
module (front) before removing the transition module.
When inserting a card—always insert the transition
module (back) before inserting the processing module.