beautypg.com

Hot swapping, Hot swapping an mp card, Hot swapping -10 – Paradyne Jetstream CPX-1000 User Manual

Page 124: Hot swapping an mp card -10

background image

5. Repair Procedures

1000-A2-GN22-00

5-10

February 2003

Step 8

Snap the card ejectors into the locked position.

Hot Swapping

Hot swapping lets you remove and replace cards without shutting
down and reconfiguring the CPX. To hot swap:

an MP card—go to Hot Swapping an MP Card, below

CP and HSC cards—go to page

5-11

Line cards—go to page

5-11

Hot Swapping
an MP Card

To hot swap an MP card, refer to JetVision User’s Guide and:

Step 1

Back up the current CPX database.

Step 2

Click the MP card in the Tree or Shelf views.

Step 3

Select Remove Resources from the Configuration menu. A
prompt displays to confirm you want to remove the resources.

Step 4

Click Yes. The card is removed from the Tree and Shelf views.

Step 5

Remove and replace with the new cards per

Removing and

Replacing Cards

on page

5-9

.

Step 6

Select Refresh CPX from the File menu. The new MP card
appears in the Tree and Shelf views.

Step 7

Restore the CPX configuration.

Important

Do not force the card into place—this may cause damage to
the connector pins.

Notes

Make sure to put on an anti-static wrist wrap when hot
swapping cards. Refer to JetVision User’s Guide.

When removing a card—always remove the processing
module (front) before removing the transition module.

When inserting a card—always insert the transition
module (back) before inserting the processing module.