beautypg.com

Paradyne Jetstream CPX-1000 User Manual

Page 107

background image

February 2003

4-7

1000-A2-GN22-00

4. Troubleshooting

2.

Refer to

Table 4–4

when troubleshooting the CP module.

3.

Refer to

Table 4–5

when troubleshooting the MP module.

4.

Refer to

Table 4–6

when troubleshooting the TDM T1

module.

5.

Refer to

Table 4–7

when troubleshooting the ATM module.

6.

Refer to

Table 4–8

when troubleshooting the LAN port.

Voice/Data Interruption

Do not press the

RST

button on the CP module. Doing so

resets the CPX shelf and interrupts all calls.

Table 4–4. CP Module Troubleshooting

Symptom

Probable Causes

Corrective Action

PWR

indicator is off.

CPX is not powered up.

Verify CPX is receiving –48 Vdc
from plant battery.

CP module did not
initialize properly upon
system power-up.

Turn CPX rear circuit breaker off,
then on again to cycle power and
reinitialize.

CP module is faulty.

Replace module (

Hot Swapping CP

and HSC Cards on page 5-11

).