2 post error beep codes, Post error beep codes 27, Table 2-11 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual
Page 73: Bmc-generated post b
Chapter 2
NAS Head
2-27
2.6.2
POST Error Beep Codes
The tables in this section list the POST error beep codes. Prior to system video
initialization, the BIOS and BMC use these beep codes to notify users of error
conditions.
8305
Hotswap controller failed to function
Yes
8420
Intelligent System Monitoring chassis opened
Yes
84F1
Intelligent System Monitoring forced shutdown
Yes
84F2
Server Management Interface failed
Yes
84F3
BMC in update mode
Yes
84F4
Sensor Data Record (SDR) empty
Yes
84FF
System event log full
No
8500
Bad or missing memory in slot 3A
Yes
8501
Bad or missing memory in slot 2A
Yes
8502
Bad or missing memory in slot 1A
Yes
8504
Bad or missing memory in slot 3B
Yes
8505
Bad or missing memory in slot 2B
Yes
8506
Bad or missing memory in slot 1B
Yes
8601
All memory marked as fail: forcing minimum back online
Yes
TABLE 2-11
BMC-Generated POST Beep Codes
Beep Code
1
Description
1
One short beep before boot (normal, not an error)
1-2
Search for option ROMs. One long beep and two short beeps on checksum
failure.
1-2-2-3
BIOS ROM checksum
1-3-1-1
Test DRAM refresh
1-3-1-3
Test 8742 keyboard controller
1-3-3-1
Auto size DRAM. System BIOS stops execution here if the BIOS does not
detect any usable memory DIMMs.
1-3-4-1
Base RAM failure. BIOS stops execution here if entire memory is bad.
TABLE 2-10
Extended POST Error Messages and Codes (Continued)
Error Code
Error Message
Pause On Boot