Table 2-10, Exte – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual
Page 72
2-26
Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004
TABLE 2-10
Extended POST Error Messages and Codes
Error Code
Error Message
Pause On Boot
8100
Processor 1 failed BIST
No
8101
Processor 2 failed BIST
No
8110
Processor 1 internal error (IERR)
No
8111
Processor 2 internal error (IERR)
No
8120
Processor 1 thermal trip error
No
8121
Processor 2 thermal trip error
No
8130
Processor 1 disabled
No
8131
Processor 2 disabled
No
8140
Processor 1 failed FRB-3 timer
No
8141
Processor 2 failed FRB-3 timer
No
8150
Processor 1 failed initialization on last boot.
No
8151
Processor 2 failed initialization on last boot.
No
8160
Processor 01: unable to apply BIOS update
Yes
8161
Processor 02: unable to apply BIOS update
Yes
8170
Processor P1 :L2 cache failed
Yes
8171
Processor P2 :L2 cache failed
Yes
8180
BIOS does not support current stepping for Processor P1
Yes
8181
BIOS does not support current stepping for Processor P2
Yes
8190
Watchdog timer failed on last boot
No
8191
4:1 core to bus ratio: processor cache disabled
Yes
8192
L2 Cache size mismatch
Yes
8193
CPUID, processor stepping are different
Yes
8194
CPUID, processor family are different
Yes
8195
Front side bus speed mismatch: System halted
Yes, Halt
8196
Processor models are different
Yes
8197
CPU speed mismatch
Yes
8198
Failed to load processor microcode
Yes
8300
Baseboard Management Controller (BMC) failed to function
Yes
8301
Front panel controller failed to function
Yes