Sun Microsystems SUN STOREDGETM 5310 NAS User Manual
Page 215
Chapter 3
Storage Arrays
3-15
Cache Active light is off - The cache contains no data. Go to step 8.
Cache Active light is illuminated - Write-back caching is enabled and data is in the
cache. Wait for the data to clear from the cache memory and for the Fast Write Cache
or Cache Active light to turn off, and then go to step 8. For information on cache
memory protection and settings, refer to the Array Management Window online
help.
Caution –
Potential damage to drives and data loss. Turning the power off and on
without waiting for the disk drives to spin down can damage the drives and may
cause data loss. Always let at least 30 seconds elapse from when you turn off the
power until you turn it on again.
8. Turn off both power switches on the back of the command module.
8
Cache
Active
Green
On
Off (if
cache
enabled)
“Replacing
a Power
Supply” on
page 7-41
9
Fault
Amber
Off
On
10
Drive Link
Green
On
Off
11
Expansion
Port
Bypass
Amber
Off
On
Fan
12
Fan Fault
Amber
Off
On
“Replacing
a Fan” on
page 7-39
Power Supply
13
Power
Green
On
Off
“Replacing
a Power
Supply” on
page 7-41
14
Fault
Amber
Off
On
Link Rate
15
2 Gb/s
Link Rate
Green
On
Not
Applicable
Not
Applicable
16
Tray ID
Conflict
Amber
Off
On - Tray
IDs
incorrect
“Setting
the Tray ID
Switch” on
page 3-29
TABLE 3-1
Lights on the Back of a Command Module
Location
Component
Light
Color
Normal Status
Problem
Status
Procedure