Siemens IK PI · 2004

6/60

AS-Interface Slaves

Digital I/O modules IP67 - K45

I/O modules for operation in the field

6

Technical specifications (continued)

K45 mounting plate

Hub

Cable end piece

For wall mounting

For standard rail
mounting

--

--

3RK1 901-2EA00

3RK1 901-2DA00

3RK1 901-1NN00

3RK1 901-1MN00

Ambient temperature in °C

-40 to +85

-40 to +85

-40 to +85

40 to +85

Degree of protection

IP67 with K45 compact
module screwed on

IP67 with K45 compact
module screwed on

IP65 with upper part
screwed on

IP67 with shaped AS-
Interface cable inserted

Connection technique

For shaped AS-Interface
cable, contacted through
the insulation-piercing ter-
minals integral to the com-
pact module

For shaped AS-Interface
cable, contacted through
the insulation-piercing ter-
minals integral to the com-
pact module

For yellow or black,
shaped AS-Interface
cable, contacted through
the insulation-piercing ter-
minals integral to the
upper part

Heavy-gauge threaded-
joint connector with inte-
grated seal (seal shaped
for AS-Interface cable)

Mounting

• Wall mounting

• On shaped bracket

(the corresponding slide
rings are required)

• Hole spacing compati-

ble with K60 mounting
plate

• Standard mounting

rail/wall mounting

• On shaped bracket

(the corresponding slide
rings are required)

• Hole spacing compati-

ble to coupling module
FK/FK-E (application
module)

• Standard mounting

rail/wall mounting

• On shaped bracket

(the corresponding slide
rings are required)

• Hole spacing compati-

ble to coupling module
FK/FK-E (application
module)

Cable end piece can be
fixed, for example, to a
machine by means of
integral ring

Note

The yellow and black
AS-Interface cable can
be inserted from any
direction

The yellow and black
AS-Interface cable can
be inserted from any
direction

Distributors can be
used for the following
purposes:

• Configuration of

network structures
(branch function)

• Isolation of cable

segments (isolating
function)

• Sealing cable ends

inside the module
(sealing function)

If one or both cables
terminate in the module,
seals are required
(straight and shaped)
that can be inserted in the
lower part of the distribu-
tor.

These seals are not
included in the scope
of supply and must be
ordered separately
(3RK1 902-0AR00).

If both cables are routed
into and out of the mod-
ule, additional seals are
not required.

--