AS-Interface light curtains and light arrays
for Category 4

AS-Interface Safety at work

6

Technical specifications

1) From interruption of the protective zone to the cut-out command on AS-Interface

Technical specifications common to all AS-Interface light curtains and light arrays

Safety classification

Type 4 according to IEC 61496-1, -2 or EN 61496-1 (self-monitoring)

Height of protective zone in mm

150 to 1800 (for series with 14 and 30 mm resolution)
450 to 3000 (for series with 50 mm resolution)
750 to 3000 (for series with 90 mm resolution)

Width of protective zone,
sensing range in m

0.3 to 6 (for series with 14 mm resolution)
0.8 to 18 (for series with 30, 50 and 90 mm resolution as well as for light arrays)
0.6 to 60 (for light arrays)

Detection capability

14 mm, 30 mm, 50 mm or 90 mm or complete persons with 2, 3 or 4 beams

Response time of the
safety equipment in ms

1)

12 to 44, d-scan 15 to 83 (for 14 mm resolution)
12 to 25, d-scan 15 to 44 (for 30 mm resolution)
< 22, d-scan 38 (for 50 mm resolution)
< 18, d-scan 25 (for 90 mm resolution)

Response time of the
complete system

Response time 3SF7842 + response time of AS-Interface safety monitor (max. 40 ms)

Degree of protection

IP65

Supply current in mA

Max. 130 (transmitter)
Max 140 (receiver)

Operating mode

Protection mode without restart lockout

Transmitter/receiver synchronization

Optical synchronization, two transmission channels can be selected

Infra-red disturbance suppression

Two techniques for selection:
Standard = high suppression
d-scan = extremely high degree of suppression

Cross-section in mm

55 * 52

Length in mm

234 to 3084 (depending on height of protective zone)

Air humidity in %

15 to 95

Operating temperature in °C

0 to +55

Storage temperature in °C

-25 to +70

Supply voltage in V

26.5 to 31.6 (according to AS-Interface specification)

ID-code receiver

B

I/O-code receiver

0 (four data bits as outputs)

Slave address receiver

Active bus component, programmed by the user in the range 1 to 31
(delivery status = bus address 0), supply voltage from the AS-Interface network

Slave address transmitter

Passive bus component (no bus address), supply voltage from the AS-Interface network

Cycle time in ms

5 (according to AS-Interface specification)

AS-Interface profile

Safe slave

Electrical connection

M 12 plug:
Pin 1 = ASI+
Pin 3 = ASI-