beautypg.com

As-interface position switches, As-interface, As-interface safety at work – Siemens ISI EN 50295 User Manual

Page 15

background image

Siemens IK PI · 2004

6/15

AS-Interface

AS-Interface Safety at work

AS-Interface position switches

6

Overview

Position switch from left to right:
Standard / Standard, with M12 connector / with tumbler

It is also possible now to directly connect SIGUARD position
switches via the standard AS-Interface with safety-oriented com-
munication. In this case, the safety functions no longer have to
be conventionally wired up.

Position switches convert the mechanical positions of moving
machine components into electrical signals.

Application

Position switch with separate actuator

The position switches with separate actuator are used in appli-
cations in which the position of doors, covers or guards has to
be monitored for safety reasons.

The position switch can only be switched using the associated
coded actuator. It is not possible to bypass it manually or using
a tool.

Position switch with tumbler

The position switches with tumblers are special safety devices
that prevent the inadvertent or intentional opening of protective
doors, guards or other covers when a dangerous state exists,
e.g. for coastdown movements of the switched-off machine.

The safety switch with tumbler has two main tasks:

• Enabling the machine when the protective device is closed

and locked

• Disabling the machine when the protective device is open

The position switch can only be switched using the associated
coded actuator. It is not possible to bypass it manually or using
a tool.

Selection and Ordering data

Design

Order No.

AS-Interface position switch, standard
Via AS-Interface F adaptor
With direct connection of AS-Interface to Safety at Work
For use up to Category 2 acc. to EN 954-1
IP65

3SF3 200-6EV00-0BA1

Molded plastic enclosure

, EN 50 047, 31 mm wide, slow-action contact, two NC

- Overtravel plunger

3SF3 200-6CV00-0BA1

- Roller plunger

3SF3 200-6DV00-0BA1

- Roller lever

3SF3 200-6EV00-0BA1

- Angular roller lever

3SF3 200-6FV00-0BA1

- Swivel lever

3SF3 200-6GV00-0BA1

Molded plastic enclosure

, EN 50 047, 31 mm wide, snap action contact, one NC

- Overtravel plunger

3SF3 200-1CV00-0BA1

- Roller plunger

3SF3 200-1DV00-0BA1

- Roller lever

3SF3 200-1EV00-0BA1

- Angular roller lever

3SF3 200-1FV00-0BA1

- Swivel lever

3SF3 200-1GV00-0BA1

Forced opening IEC 60 947-5-1, Appendix K.