beautypg.com

As-interface, As-interface safety at work – Siemens ISI EN 50295 User Manual

Page 19

background image

Siemens IK PI · 2004

6/19

AS-Interface

AS-Interface Safety at work

AS-Interface light curtains and light arrays

for Category 4

6

Overview

The light curtains and light arrays of Category 4 acc. to EN 954-
1 offer active optical protection for persons at machines. They
can be connected to AS-Interface directly and safely as an op-
tion.

SIGUARD light curtains and light arrays are

• active opto-electronic protective devices (AOPD),

• comply with Type 4 acc. to EN 61496-1, -2,

• are EU prototype-tested,

• protect the operating personel working on or near dangerous

machines,

• operate contact-free,

• are free of wear in comparison to mechanical systems (e.g.

safety mats).

For further details, see the manual "Safety Integrated“ and the
operating instructions for the respective devices.

Benefits

• Double-scan function

• Cascading of host and guest devices

• Two transmission channels

Design

A SIGUARD Light Curtain or light array comprises a transmitter
and a receiver that must be mounted opposite each other.
Depending on the resolution and length, a specific number of
transmit and receive diodes are arranged in a vertical row.
The infra-red LEDs of the transmitter send short light pulses that
are received by the receive diodes.

SIGUARD Light Curtains:

• Resolution 14, 30 and 50 mm,

• Length 150 mm to 3 m,

• Cascading of master and slave devices to create larger height

or length of protective zone or for angular arrangement.

SIGUARD Light Arrays:

• 2-, 3- or 4-beam for access protection.

Standards

• EN 61 496-1, -2, IEC 61 496-1, -2 (requirements for non-contact

protection systems)

• EN 999 (incl. calculation of safety clearances)

• EN 954-1 (safety of machines, safety-related parts of controls).