Ecofast motor and soft starter, As-interface slaves – Siemens ISI EN 50295 User Manual
Page 116
Siemens IK PI · 2004
6/116
AS-Interface Slaves
ECOFAST motor and soft starter
AS-Interface motor starters and IP65/67 load feeders
6
■
Overview
Distributed motor starters are used for switching and protecting
loads locally. Versions with graded functional scope and with
different installation possibilities ensure that both the functional
requirements of the process and the constructional boundary
conditions of the machine or installation are taken into account.
Distributed motor starters are available for PROFIBUS DP and
AS-Interface.
The starters can be installed in the vicinity of the motor or
mounted onto the motor.
The following are available
• Single units for geographically distributed motors and
• Isolated solutions (ET 200X) for drives installed close together.
The functionality in the ECOFAST system ranges from direct on-
line starters, to reversing starters and soft starters through to
frequency converters (ET 200X).
Brake contacts are available as an option for the starters.
Two resp. four integrated digital contacts enable sensors to be
scanned locally.
All starters are equipped throughout with standardized inter-
faces for data and power in accordance with the ECOFAST
specification (DESINA compatible):
• HanBrid for PROFIBUS DP resp. insulation displacement
method for AS-Interface
• Han Q8 for the power supply
• Han 10e for motor connection
The starters can be connected using T pieces for data and
power to prevent interruption.
■
Selection and Ordering data
Design
Order No.
Fieldbus
interface
Switching
function
Motor
protection
Adjustment/
performance range
Brake
output
PROFIBUS
DP
Mechanical
Thermistor
0.3 to 9 A/4 kW
No
3RK1 303-2AS51-1AA0
400 V AC
3RK1 303-2AS51-1AA3
Thermal
motor model
0.3 to 3 A/1.1 kW
No
3RK1 303-5BS41-1AA0
400 V AC
3RK1 303-5BS41-1AA3
2.4 to 9 A/4 kW
No
3RK1 303-5CS41-1AA0
400 V AC
3RK1 303-5CS41-1AA3
Electronic, soft
Full motor
protection
0.3 to 3 A/1.1 kW
No
3RK1 303-6BS71-1AA0
400 V AC
3RK1 303-6BS71-1AA3
2.4 to 12 A/5.5 kW
No
3RK1 303-6DS71-1AA0
400 V AC
3RK1 303-6DS71-1AA3
electronic soft,
several speeds,
R255
0.6 to 4 A/1.5 kW
400 V AC
3RK1 303-6ES81-3AA3
AS-Interface Mechanical
Thermistor
0.3 to 9 A/4 kW
No
3RK1 323-2AS51-1AA0
400 V AC
3RK1 323-2AS51-1AA3
Thermal
motor model
0.3 to 3 A/1.1 kW
No
3RK1 323-5BS41-1AA0
400 V AC
3RK1 323-5BS41-1AA3
2.4 to 9 A/4 kW
No
3RK1 323-5CS41-1AA0
400 V AC
3RK1 323-5CS41-1AA3
Electronic, soft
Full motor
protection
0.3 to 3 A/1.1 kW
No
3RK1 323-6BS71-1AA0
400 V AC
3RK1 323-6BS71-1AA3
2.4 to 12 A/5.5 kW
No
3RK1 323-6DS71-1AA0
400 V AC
3RK1 323-6DS71-1AA3
electronic soft,
several speeds,
R255
0.6 to 4 A/1.5 kW
400 V AC
3RK1 323-6ES81-3AA3
Micro Starter
mechanical
Thermistor
0.3 to 9 A/4 kW
No
see Catalog M11