As-interface slaves, As-interface motor starters and ip20 load feeders, As-interface load feeder modules ip20 – Siemens ISI EN 50295 User Manual
Page 119
Siemens IK PI · 2004
6/119
AS-Interface Slaves
AS-Interface motor starters and IP20 load feeders
AS-Interface load feeder modules IP20
6
■
Selection and Ordering data
1) Complete feeders with AS-Interface load feeder module:
See Catalog LV 10 Section "Load Feeders and Soft Starters"
2) Without connectors for data and auxiliary power (yellow and black).
3) With one connector each for data and auxiliary power (yellow and red).
4) Busbar accessories: See Catalog LV 10 Section "Load Feeders and Soft Starters"
and "Distribution Systems, Busbar Systems and Switchgear"
Design
Order No.
3RK1 400-1KG01-0AA1
3RK1 400-1MG01-0AA1
AS-Interface load feeder module
1
)
For mounting onto standard rails
For contactors sizes S00 and S0
For mounting on 40 mm or 60 mm busbar systems and SIRIUS standard rail
adapters, the matching carrier is required (see Accessories)
The AS-Interface connectors for the data and auxiliary power cable (yellow and
black) must be ordered separately (see Accessories)
Type
Supply in V
2 inputs /
1 output
24 DC
2
)
3RK1 400-1KG01-0AA1
4 inputs/
2 outputs
3RK1 400-1MG01-0AA1
2 inputs /
1 relay output
120/230 AC
3
)
3RK1 402-3KG02-0AA1
3 inputs /
2 relay outputs
3RK1 402-3LG02-0AA1
Accessories
4)
Manual for AS-Interface load feeder module
• German, English
3RK1 701-2GB00-0AA0
• Italian, French
3RK1 701-2HB00-0AA0
Carrier with mounted power
connector coupling
Carrier for AS-Interface load feeder module
• With PE and N conductor connection,
for mounting on busbar adapter with 40 mm rail center-line spacing
Power connector set 3RK1 901-0EA00 is necessary
- 45 mm
3RK1 901-3AA00
- 54 mm
3RK1 901-3BA00
• With PE and N conductor connection,
for mounting on busbar adapter with 60 mm rail center-line spacing
Power connector set 3RK1 901-0EA00 is necessary
- 45 mm
3RK1 901-3CA00
- 54 mm
3RK1 901-3DA00
• Without PE and N conductor connection,
for mounting on busbar adapter with 40 mm or 60 mm rail center-line spacing
- 45 mm
3RK1 901-3EA00
- 54 mm
3RK1 901-3FA00
• for mounting on SIRIUS adapter 3RA19 22-1A for rail mounting
45 mm
3RK1 901-3GA00
3RK1 901-0EA00
Power connector set
5-pole, 2.5 mm
2
(one set contains five connectors and five couplings)
3RK1 901-0EA00
3RK1 901-0NA00
3RK1 901-0PA00
AS-Interface connectors for data and auxiliary power cable
With insulation-piercing terminals for 2
´ (0.5 to 0.75 mm
2
)
standard stranded conductors
(one packing contains five connectors)
• Yellow
3RK1 901-0NA00
• Black
3RK1 901-0PA00