Silex technology Embedded Intelligent Module SX-560 User Manual
Page 62

Page 56
Silex
Advanced Configuration
Part Number
140-00192-100
Table 23 GPIO Transmit Commands
Command
Description
SET GPIO TRANsmit
Sets the string that will be included in an Email alert if
the trigger is activated. These strings are also used to
identify the trigger on the trap and alert web pages. This
value overrides the default string created when the
trigger is enabled, which is of the form “GPIO #
0|1>”.
for which the string is being set. The remainder of the
line is taken as the string for the indicated trigger
number.
SHOW GPIO TRANsmit
SHOW GPIO TRANsmit
Displays the string that will be included in an Email alert
if the trigger is activated. These strings are also used to
identify the trigger on the trap and alert web pages.
There are two forms -- one displays all strings, the other
only shows the string corresponding to a specific trigger.
CL GPIO TRANsmit
Clears the transmit string for a specified trigger
condition. If an Email alert is triggered for the condition,
no text will be included in the alert.
for which the string is being cleared.
NOTE: If a new trigger condition is set, all undefined
trigger conditions are reset to their default value.
Example:
Local> show gpio tran
Trig # Email String
------ ------------
0: GPIO #1 is 1
1: GPIO #2 is 1
Local> set gpio tran 0 your email text msg here
Local> show gpio tran
Trig # Email String
------ ------------
0: your email text msg here
1: GPIO #2 is 1
Local> show gpio tran 1
1: GPIO #1 is 1
Table 24 GPIO Data Commands