Siemens MICROMASTER 420 User Manual
Page 68
3 Functions
Issue 07/04
MICROMASTER 420 Operating Instructions
68
6SE6400-5AA00-0BP0
Table 3-8
Example 1LA7060-4AB10
Delta
circuit
configuration
87 Hz
characteristic
Star circuit
configuration
P0304
Rated motor voltage
230 V
400 V
400 V
P0305
Rated motor current
0.73 A
0.73 A
0.42 A
P0307
Rated motor power
120 W
207 W
120 W
P0308
Cos
ϕ
0.75 0.75 0.75
P0310
Rated motor frequency
50 Hz
87 Hz
50 Hz
P0311
Rated motor speed
1350 RPM
2460 RPM
1350 RPM
P0314
Motor pole pairs
2
2
2
Contrary to the BOP, AOP operator panels or commissioning tool program
DriveMonitor, the STARTER commissioning (start-up) program offers a mask-
orientated quick commissioning, which is especially advantageous for users who
are using MICROMASTER for the first time. On the other hand, BOP, AOP and
DriveMonitor offer, in conjunction with the drive inverter, parameter-orientated
quick commissioning where the user is navigated through the menu tree mentioned
above.
NOTE
The MICROMASTER series of drive units is not available for 3-ph. 690 V AC.