Siemens MICROMASTER 420 User Manual

Page 118

background image

3 Functions

Issue 07/04

MICROMASTER 420 Operating Instructions

118

6SE6400-5AA00-0BP0

Table 3-21

Possible parameter settings for P0719

Value

Command source

Setpoint source

0

Cmd = BICO parameter

Setpoint = BICO parameter

1

Cmd = BICO parameter

Setpoint = MOP setpoint

2

Cmd = BICO parameter

Setpoint = Analog setpoint

3

Cmd = BICO parameter

Setpoint = Fixed frequency

4

Cmd = BICO parameter

Setpoint = USS on BOP link

5

Cmd = BICO parameter

Setpoint = USS on COM link

6

Cmd = BICO parameter

Setpoint = CB on COM link

10

Cmd = BOP

Setpoint = BICO parameter

11

Cmd = BOP

Setpoint = MOP setpoint

12

Cmd = BOP

Setpoint = Analog setpoint

13

Cmd = BOP

Setpoint = Fixed frequency

15

Cmd = BOP

Setpoint = USS on BOP link

16

Cmd = BOP

Setpoint = USS on COM link

40

Cmd = USS on BOP link

Setpoint = BICO parameter

41

Cmd = USS on BOP link

Setpoint = MOP setpoint

42

Cmd = USS on BOP link

Setpoint = Analog setpoint

43

Cmd = USS on BOP link

Setpoint = Fixed frequency.

44

Cmd = USS on BOP link

Setpoint = USS on BOP link

45

Cmd = USS on BOP link

Setpoint = USS on COM link

46

Cmd = USS on BOP link

Setpoint = CB on COM link

50

Cmd = USS on COM link

Setpoint = BICO parameter

51

Cmd = USS on COM link

Setpoint = MOP setpoint

52

Cmd = USS on COM link

Setpoint = Analog setpoint

53

Cmd = USS on COM link

Setpoint = Fixed frequency

54

Cmd = USS on COM link

Setpoint = USS on BOP link

55

Cmd = USS on COM link

Setpoint = USS on COM link

60

Cmd = CB on COM link

Setpoint = BICO parameter

61

Cmd = CB on COM link

Setpoint = MOP setpoint

62

Cmd = CB on COM link

Setpoint = Analog setpoint

63

Cmd = CB on COM link

Setpoint = Fixed frequency

64

Cmd = CB on COM link

Setpoint = USS on BOP link

66

Cmd = CB on COM link

Setpoint = USS on COM link