Siemens MICROMASTER 420 User Manual
Page 118
3 Functions
Issue 07/04
MICROMASTER 420 Operating Instructions
118
6SE6400-5AA00-0BP0
Table 3-21
Possible parameter settings for P0719
Value
Command source
Setpoint source
0
Cmd = BICO parameter
Setpoint = BICO parameter
1
Cmd = BICO parameter
Setpoint = MOP setpoint
2
Cmd = BICO parameter
Setpoint = Analog setpoint
3
Cmd = BICO parameter
Setpoint = Fixed frequency
4
Cmd = BICO parameter
Setpoint = USS on BOP link
5
Cmd = BICO parameter
Setpoint = USS on COM link
6
Cmd = BICO parameter
Setpoint = CB on COM link
10
Cmd = BOP
Setpoint = BICO parameter
11
Cmd = BOP
Setpoint = MOP setpoint
12
Cmd = BOP
Setpoint = Analog setpoint
13
Cmd = BOP
Setpoint = Fixed frequency
15
Cmd = BOP
Setpoint = USS on BOP link
16
Cmd = BOP
Setpoint = USS on COM link
40
Cmd = USS on BOP link
Setpoint = BICO parameter
41
Cmd = USS on BOP link
Setpoint = MOP setpoint
42
Cmd = USS on BOP link
Setpoint = Analog setpoint
43
Cmd = USS on BOP link
Setpoint = Fixed frequency.
44
Cmd = USS on BOP link
Setpoint = USS on BOP link
45
Cmd = USS on BOP link
Setpoint = USS on COM link
46
Cmd = USS on BOP link
Setpoint = CB on COM link
50
Cmd = USS on COM link
Setpoint = BICO parameter
51
Cmd = USS on COM link
Setpoint = MOP setpoint
52
Cmd = USS on COM link
Setpoint = Analog setpoint
53
Cmd = USS on COM link
Setpoint = Fixed frequency
54
Cmd = USS on COM link
Setpoint = USS on BOP link
55
Cmd = USS on COM link
Setpoint = USS on COM link
60
Cmd = CB on COM link
Setpoint = BICO parameter
61
Cmd = CB on COM link
Setpoint = MOP setpoint
62
Cmd = CB on COM link
Setpoint = Analog setpoint
63
Cmd = CB on COM link
Setpoint = Fixed frequency
64
Cmd = CB on COM link
Setpoint = USS on BOP link
66
Cmd = CB on COM link
Setpoint = USS on COM link