5 MICROMASTER 420 specifications

Issue 07/04

MICROMASTER 420 Operating Instructions

158

6SE6400-5AA00-0BP0

Table 5-1

MICROMASTER Performance Ratings

Feature Specification

Mains operating voltage
and
Power ranges

1 AC 200 V to 240 V

±

10 %

0,12 kW – 3,0 kW

(0,16 hp – 4,0 hp)

3 AC 200 V to 240 V

±

10 %

0,12 kW – 5,5 kW

(0,16 hp – 7,5 hp)

3 AC 380 V to 480 V

±

10 %

0,37 kW – 11,0 kW (0,50 hp – 15,0 hp)

Input frequency

47 Hz to 63 Hz

Output frequency

0 Hz to 650 Hz

Power factor

0,7

Inverter efficiency

96 % to 97 %

Overload capability

50 % overload capability for 60 s within 5 min period referred to the rated output
current

Inrush current

Less than nominal input current

Control method

Linear V/f Control; Linear V/f with Flux Current Control (FCC),
Quadratic V/f Control; Multi-point V/f control

Pulse frequency

2 kHz to 16 kHz (2 kHz steps)

Fixed frequencies

7, programmable

Skip frequencies

4, programmable

Setpoint resolution

0.01 Hz Digital, 0.01 Hz Serial, 10 bit Analogue
(motor potentiometer 0.1 Hz [0.1% (in PID mode)])

Digital inputs

3, programmable (isolated), switchable active high / active low (PNP/NPN)

Analogue input

1, (0 to 10 V) used for frequency setpoint or PI feedback signal, scalable or
usable as 4

th

digital input

Relay output

1, programmable 30 V DC / 5 A (resistive), 250 V AC / 2 A (inductive)

Analogue output

1, programmable (0 mA to 20 mA)

Serial interface

RS-485, Option RS-232

Electromagnetic compatibility

Optional EMC filters to EN55011 Class A or B,
also Internal Class A filters available

Braking

DC braking, compound braking

Protection level

IP20

Temperature range

-10

°

C to +50

°

C (14

°

F to 122

°

F)

Storage temperature

-40

°

C to +70

°

C (-40

°

F to 158

°

F)

Humidity

< 95 % RH – non-condensing

Operational altitudes

up to 1000 m above sea level without derating

Protection features

Undervoltage , Overvoltage, Overload, Ground Faults, Short circuit, Stall
Prevention, Motor Blocking Protection, Motor Overtemperature, Inverter
Overtemperature, Parameter Interlock

Standards

UL, cUL, CE, C-tick

CE Marked

Conformity with EC Low Voltage Directive 73/23/EEC
and Electromagnetic Compatibility Directive 89/336/EEC