Issue 07/04

3 Functions

MICROMASTER 420 Operating Instructions

6SE6400-5AA00-0BP0

61

3.5.1

50/60 Hz setting

The frequency setting made in the factory can be adapted to the North American
market, without requiring any parameterization using an operator panel or PC tool
using the 50/60 Hz DIP switch (refer to Fig. 3-15).

50/60 Hz DIP switch
for frequency setting

60 Hz

50 Hz

Fig. 3-15

DIP switch to change-over between 50/60 Hz

The switch determines the value of parameter P0100 corresponding to the
following diagram (refer to Fig. 3-16). Besides P0100 = 2, after the power supply
voltage has been switched-in, the 50/60 Hz DIP switch determines the 50/60 Hz
setting (value of parameter P0100).

P0100 = 2

?

P0100 = 0

P0100 = 2

P0100 = 1

P0100 = 2

?

P0100 = 1

?

yes

yes

no

no

yes

yes

no

no

Quick

commissioning

P0010 = 1

Power

cycle

DIP2 = OFF

?

Power in kW

Frequency 50 Hz

Power in kW

Frequency 60 Hz

Power in hp

Frequency 60 Hz

Fig. 3-16

Mode of operation of the 50/60 Hz DIP switch in conjunction with P0100