beautypg.com

2 ramp-function generator (rfg), With ro undin g – Siemens MICROMASTER 420 User Manual

Page 112

background image

3 Functions

Issue 07/04

MICROMASTER 420 Operating Instructions

112

6SE6400-5AA00-0BP0

3.12.2

Ramp-function generator (RFG)

Parameter range:

P1120, P1121

r1119, r1170

P1130 – P1142

Warnings -
Faults -

Function chart number:

FP5000, FP5300

The ramp-function generator is used to limit the acceleration when the setpoint
changes according to a step function. This therefore helps to reduce the stressing
on the mechanical system of the machine. An acceleration ramp and a braking
ramp can be set independently of one another using the ramp-up time P1120 and
the ramp-down time P1121. This allows a controlled transition when the setpoint is
changed (refer to Fig. 3-42).

Without roun

ding

t

f

f

max

P1120

P1121

f

2

f

1

f

f

max

P1133

P1132

P1131

P1130

t

f

2

f

1

t

up

t

down

With ro

undin

g

for

P1131)

P1130

(

2

1

P1120

P1082

f

-

f

1

2

+

P1120

P1082

f

-

f

P1131)

P1130

(

2

1

t

1

2

up

+

+

=

for

P1133)

P1132

(

2

1

P1121

P1082

f

-

f

1

2

+

P1121

P1082

f

-

f

P1133)

P1132

(

2

1

t

1

2

down

+

+

=

Fig. 3-42

Ramp-function generator