3 Functions
Issue 07/04
MICROMASTER 420 Operating Instructions
112
6SE6400-5AA00-0BP0
3.12.2
Ramp-function generator (RFG)
Parameter range:
P1120, P1121
r1119, r1170
P1130 – P1142
Warnings -
Faults -
Function chart number:
FP5000, FP5300
The ramp-function generator is used to limit the acceleration when the setpoint
changes according to a step function. This therefore helps to reduce the stressing
on the mechanical system of the machine. An acceleration ramp and a braking
ramp can be set independently of one another using the ramp-up time P1120 and
the ramp-down time P1121. This allows a controlled transition when the setpoint is
changed (refer to Fig. 3-42).