Mocomtech CIM-550 User Manual

Page 95

background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

Remote Control

CD/CIM550.IOM

69

Parameter
Type

Command
(Instruction

Code and
qualifier)

Arguments for

Command or

Response to
Query

Description of arguments
(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query
(Instruction

Code and
qualifier)

Response to

query
(target to
controller)

define the unit as being an EDMAC Master.
This command is only valid for an EDMAC master.
When used as a Query, it may be sent to an

EDMAC slave, which will respond with the

appropriate address.

Circuit ID

string

CID= 24

bytes,

ASCII

Command or Query.
Sets or queries the user-defined Circuit ID string,
which is a fixed length of 24 characters.
Valid characters include:
Space ( ) * + - , . / 0-9 and A-Z.

CID= (message ok)
CID? (received ok,
but invalid arguments found)

CID?

CID=xxxxxxxx
xxxxxxxxxxxxxx
x (same format

as command

arguments)

Outdoor Unit

Comms

ODU=

1 byte, value of

0 or 1

Command or Query.
Enables or disables communication, via an FSK

serial link, with a Comtech Transceiver (Outdoor
unit).
0 = disabled
1 = enabled
Example: ODU=0

ODU= (message ok)
ODU? (received ok,
but invalid arguments found)
ODU* (message ok, but not

permitted in current mode)

ODU? ODU=x

(same format as

command
arguments)

AUPC
Enable

AUP=

1 byte, value of

0 or 1

Command or Query.
Enables or disables AUPC (Automatic Uplink
Power Control). 0 = disabled 1 = enabled
Example: APC=0
Note: Framing must be selected for the AUPC

feature to work. If AUPC is selected when Framing
is disabled, APC* will be returned

AUP= (message ok)
AUP? (received ok,
but invalid arguments found)
AUP* (message ok, but not

permitted in current mode)

AUP? AUP=x

(same format as
command

arguments)

AUPC
Parameters

APP=

6 bytes,

Command or Query.
Defines AUPC (Automatic Uplink Power Control)

operating parameters. Has the form abc.cd

Where:
a = Define action on max power condition:

APP= (message ok)
APP? (received ok,
but invalid arguments found)
APP* (message ok, but not

permitted in current mode)

APP? APP=abc.cd

(same format as

command

arguments)