Mocomtech CIM-550 User Manual
Page 101
CiM-550 IP Enabled Satellite Modem
Rev. 2
Remote Control
CD/CIM550.IOM
75
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric
codes, that is, ASCII codes between 48 and 57)
Response to Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Interval
SSI=x, where x = 0 to 9 in 10 minute steps. Note:
setting this parameter to 0 disables the statistics
logging function. Example: SSI=3 means 30
minutes
SSI* (message ok, but not
permitted in current mode)
argument)
Clear All
Stored
Statistics
CAS= None
Command
only
Instructs the unit to clear all Stored Statistics
This command takes no arguments.
CAS= (message ok)
N/A
N/A
Retrieve
next 5
unread
Stored
Events
N/A
75 bytes
Query only
Unit returns the oldest 5 Stored Events which have
not yet been read over the remote control. Reply
format: {CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body, where Sub-
body=
ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
and C being the fault code, as defined under the
‘FLT’ message table entry, except Info codes,
which are: 0=power off, 1=power on, 2=log
cleared, 3=global config change, and 4=
redundancy config change. If there are no new
events, the unit replies with RNE? If there are less
N/A RNE?
RNE={CR}ABC
ddmmyyhhmms
s{CR}ABCddm
myyhhmmss{C
R}ABCddmmyy
hhmmss{CR}AB
Cddmmyyhhmm
ss{CR}ABCddm
myyhhmmss
(see description
for details of
arguments)