CiM-550 IP Enabled Satellite Modem

Rev. 2

Remote Control

CD/CIM550.IOM

75

Parameter
Type

Command
(Instruction

Code and
qualifier)

Arguments for

Command or

Response to
Query

Description of arguments
(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query
(Instruction

Code and
qualifier)

Response to

query
(target to
controller)

Interval

SSI=x, where x = 0 to 9 in 10 minute steps. Note:
setting this parameter to 0 disables the statistics

logging function. Example: SSI=3 means 30

minutes

SSI* (message ok, but not
permitted in current mode)

argument)

Clear All

Stored

Statistics

CAS= None

Command

only

Instructs the unit to clear all Stored Statistics
This command takes no arguments.

CAS= (message ok)

N/A

N/A

Retrieve
next 5

unread

Stored

Events

N/A

75 bytes

Query only
Unit returns the oldest 5 Stored Events which have

not yet been read over the remote control. Reply

format: {CR}Sub-body{CR}Sub-body{CR}Sub-

body{CR}Sub-body{CR}Sub-body, where Sub-
body=
ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
and C being the fault code, as defined under the
‘FLT’ message table entry, except Info codes,

which are: 0=power off, 1=power on, 2=log

cleared, 3=global config change, and 4=

redundancy config change. If there are no new
events, the unit replies with RNE? If there are less

N/A RNE?

RNE={CR}ABC
ddmmyyhhmms

s{CR}ABCddm

myyhhmmss{C

R}ABCddmmyy
hhmmss{CR}AB

Cddmmyyhhmm

ss{CR}ABCddm

myyhhmmss
(see description

for details of

arguments)