2 select\monit\stats\configure, 5 select\monitor\aupc – Mocomtech CIM-550 User Manual
Page 77
CiM-550 IP Enabled Satellite Modem
Rev. 2
Front Panel Menus
CD/CIM550.IOM
51
Examples:
08.0,13.5,2.5,1.8 means:
Minimum Eb/No observed in the measurement interval = 8.0 dB
Average Eb/No observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB
Average TPLI observed in the measurement interval = 1.8 dB
LOSS,04.5,0.0,0.0 means:
There was a loss of demod lock during the measurement interval
Average Eb/No observed in the measurement interval = 4.5 dB
Maximum TPLI observed in the measurement interval = 0 dB
Average TPLI observed in the measurement interval = 0 dB
(Which indicates no AUPC activity, or that AUPC is disabled.)
If the user selects CLEAR, the statistics log is cleared, and the user is taken directly back
to the previous menu.
4.1.7.4.2 SELECT\MONIT\STATS\CONFIGURE
DISPLAY SELECTIONS/DESCRIPTION
LOGGING INTERVAL:90 MINS
(SET 00 TO DISABLE)(ENT)
The user is prompted to enter the logging interval
(the period of time over which the statistics will be
measured).
The user can choose 10, 20, 30, 40, 50, 60, 70, 80,
or 90 minutes.
4.1.7.5 SELECT\MONITOR\AUPC
DISPLAY SELECTIONS/DESCRIPTION
FRAMING NOT ENABLED!
(PRESS ENTER)
If AUPC is selected, and the modem is not in
Framed mode, this menu is displayed.
AUPC: REMOTE Eb/No=14.0dB
TX POWER INCREASE=2.2dB
If AUPC is selected, and the modem is in Framed
mode, this menu is displayed. The top line displays the
value of Eb/No of the demodulator at the distant end of
the satellite link. The Eb/No will display UNLOCK if the
remote demod is unlocked. The bottom line shows
how much the AUPC system has increased the output
power. If AUPC is not enabled, the value of TX
POWER INCREASE will show as 0.0 dB.